Passive and weight bearing knee kinematics of 8 patients undergoing total knee arthroplasty
This database includes motion capture of the knee kinematics of 8 patients (mean ± SD: age, 70.4 ± 8.9 years; height, 161.9 ± 10 cm; weight, 78.6 ± 26.7 kg; 7 females) with end-stage knee osteoarthritis (grade III to IV on the Kellgren–Lawrence classification) that underwent total knee arthroplasty. Patients performed a standardized barefoot treadmill gait analysis using the KneeKG™ system (Emovi, Montreal, Canada) one week before and three months after TKA. Additionally, passive flexion-extension was recorded before and after total knee arthroplasty implantation using the Knee 3 computer assisted surgery system (Brainlab, Munich, Germany). The anatomical axes of the KneeKG™ and CAS systems were homogenised using two-level, multi-body kinematics optimisation. Knee kinematics computations followed the International Society of Biomechanics conventions.
- Organizational unit
- Laboratory of Kinesiology
- Type
- Dataset
- DOI
- License
- Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International
- Keywords
- Total knee arthroplasty, Gait analysis, Computer-Assisted Surgery, Navigation, KneeKG, Knee Kinematics
Contributors
- Gasparutto, Xavier
- Bonnefoy-Mazure, Alice
- Attias, Michael
- Dumas, Raphaël
- Armand, Stéphane
- Miozzari, Hermès
Files