Clinical Gait Analysis of 100 patients with knee osteoarthritis before and one year after total knee athroplasty and 32 control pariticpants.

This database contains the clinical gait analysis of 100 patients undergoing total knee arthroplasty for end-stage knee osteoarthritis before and one year after surgery, as well as gait analysis of 33 control participants. The data include: - Participant's characteristics (Sex, Age, Height, BMI, side of surgery) - Kinematic timeseries of the Trunk, Pelvis, Hip, Knee, Ankle and Foot Progression Angle computed with the Conventional Gait Model 1.0, before and one year after surgery. - Kinematic features of the Trunk, Pelvis, Hip, Knee, Ankle and Foot Progression Angle, described in the associated paper [1], before and one year after surgery. - Spatio-temporal parameters before and one year after surgery (walking speed, stride time, stride length, cadence, step time, step length, step width, foot off in % of gait cycle, percentage single support, percentage double support) - Global scores of Patient Reported Outcome Measures before and one year after surgery (Pain during walking, 12-Item Short Form Survey Physical & Mental score, Western Ontario and McMaster Universities Arthritis Index for Pain & Function, Satisfaction 1 year after surgery..) The data is associated with the following paper: [1] Gasparutto X, Bonnefoy-Mazure A, Attias M, Turcot K, Armand S, Miozzari HH. Comprehensive analysis of total knee arthroplasty kinematics and functional recovery: Exploring full-body gait deviations in patients with knee osteoarthritis. PloS one. 2024;19(12):e0314991.

    Organizational unit
    Laboratory of Kinesiology
    Type
    Dataset
    DOI
    10.26037/yareta:4xnhbsiyqrbihlep2nst2u2hyq
    License
    Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International
    Keywords
    Clinical Gait Analysis, Total Knee Arthroplasty, Knee, Osteoarthritis, Kinematics, Spatio-temporal parameter, WOMAC, SF12
Publication date14/06/2024
Retention date11/06/2039
accessLevelPublicAccess levelPublic
SensitivityBlue
licenseContract on the use of data
License
Contributors
  • Gasparutto, Xavier orcid
  • Bonnefoy-Mazure, Alice
  • Attias, Michael
  • Turcot, Katia
  • Armand, Stéphane orcid
  • Miozzari, Hermès
1
0
  • Quality (0 Reviews)
  • Usefulness (0 Reviews)

Datacite metadata

Packages information

Similar archives

Laboratory of Kinesiology
Marker misplacement of LKNE
2019 accessLevelPublic Public 2.2 MB
Laboratory of Kinesiology
Human gait and other movements - markers / inertial sensors / pressure insoles / force plates
2022 accessLevelClosed Closed 2.6 GB
Laboratory of Kinesiology
Fusion of motion capture and bi-plane x-rays
2019 accessLevelPublic Public 113.8 MB
Laboratory of Kinesiology
Impairments and sagittal kinematics of the lower limbs of children with cerebral palsy
2021 accessLevelPublic Public 990.7 KB
All rights reserved by DLCM and the University of GenevaunigeBlack